Heat pump refrigerants: R-410A, R-32 and R-454B

As of October 2026, new residential heat pumps in the U.S. must use a refrigerant with a global warming potential under 700, such as R-32 or R-454B, while existing R-410A systems can still be serviced.

Editorial staffEdited by heatpumpwiki

History 1
Contents

As of October 2026, new residential air conditioners and heat pumps in the U.S. must use a refrigerant with a global warming potential (GWP) below 700. The limit started January 1, 2025, under EPA's Technology Transitions rule.Source 1Source 2 Most new residential heat pumps now use R-32 or R-454B in place of R-410A. Existing R-410A systems can keep running and be repaired.Source 3

The three refrigerants

Refrigerant GWP (EPA reference table) GWP (EPA SNAP page) ASHRAE safety class listed by EPA
R-410A 2,088 2,090 not A2L
R-32 (HFC-32) 675 675 A2L
R-454B 465 470 A2L

GWP values are from EPA's Technology Transitions GWP Reference TableSource 4 and EPA's SNAP page for residential air conditioning and heat pumps.Source 5 The two EPA pages round differently, so the numbers for R-410A and R-454B differ slightly between them. EPA's SNAP page lists R-32 and R-454B with the A2L safety classification.Source 5

GWP compares how much heat a gas traps relative to carbon dioxide over a set period.

What A2L means

The A2L label comes from the ASHRAE Standard 34 safety classification. "A" is the lower-toxicity class. EPA training material explains the flammability classes: class 1 shows no flame propagation in the test, and flammable refrigerants are graded as 2L (lower flammability), 2 (flammable) and 3 (higher flammability).Source 6 R-32 and R-454B are 2L. EPA's comparison shows a 2L refrigerant with a burning velocity of 1.6 cm/s against 46 cm/s for a class 3 refrigerant.Source 6

EPA lists R-454B as "acceptable with use conditions," which refers to the safety conditions in the rule that listed it.Source 5 The installation manual for an A2L system sets out the requirements the installer must follow for that model.

The rule timeline, as of October 2026

EPA's rule history:Source 1

Date Action
October 24, 2023 Final Technology Transitions rule sets a GWP limit of 700 for residential and light commercial AC and heat pumps, starting January 1, 2025
December 26, 2023 Interim final rule lets equipment manufactured or imported before January 1, 2025 be installed until January 1, 2026
December 12, 2024 Rule extends installation dates for variable refrigerant flow (VRF) systems; does not change residential split systems
October 3, 2025 EPA proposes a reconsideration of parts of the rule
May 26, 2026 Final rule, effective July 27, 2026, removes the January 1, 2026 installation deadline for systems whose components were made or imported before January 1, 2025

EPA's fact sheet for the May 2026 rule says it "removes the January 1, 2026, installation compliance date" and allows pre-2025 inventory to be installed "until supply runs out."Source 1 EPA's sector page now says there is "no installation compliance date for systems where all specified components were manufactured or imported prior to January 1, 2025."Source 2

Note on conflicting EPA pages. EPA's Frequent Questions page, last updated September 14, 2026, still says that "after January 1, 2026, if a whole new system is installed it must use lower-GWP refrigerant."Source 3 That conflicts with the May 2026 rule and the sector page. The rule and the sector page are the more specific and more recent statements.

Many websites and older articles still state the January 1, 2026 installation deadline. It was removed.

If you have an R-410A system

EPA's Frequent Questions page says homeowners "can maintain and repair their systems throughout the useful life," including replacing "a faulty component (e.g., condensing unit, indoor coil...) with a similar R-410A component."Source 3 R-410A replacement components made after January 1, 2025 must be labeled "for servicing existing equipment only."Source 3 EPA also notes that "the availability of HFCs and components may lessen over time as HFCs are phased down."Source 3

Refrigerant handling of any kind requires an EPA Section 608 certified technician.Source 8

The HFC phasedown

Separately from the equipment rule, the AIM Act reduces how much HFC refrigerant can be produced and imported. The schedule in federal regulation, as a share of the baseline:Source 7

Years Allowed share of baseline
2024 to 2028 60%
2029 to 2033 30%
2034 to 2035 20%
2036 onward 15%

EPA notes that the availability of HFCs may lessen as the phasedown proceeds.Source 3

What to check when buying

  • The refrigerant listed on the outdoor unit's nameplate and in the quote.
  • For a partial replacement (outdoor unit only, or indoor coil only) on an R-410A system, ask whether the new component is an R-410A service part matched to the existing equipment.
  • For a new system, ask for the AHRI certificate, which shows the certified combination of outdoor and indoor units.
  • See Heat pump buying checklist.

Sources

  1. 1.Regulatory Actions for Technology Transitions. U.S. Environmental Protection Agency. Accessed Oct 25, 2026
  2. 2.Technology Transitions HFC Restrictions by Sector. U.S. Environmental Protection Agency. Accessed Oct 25, 2026
  3. 3.Frequent Questions on the Phasedown of Hydrofluorocarbons. U.S. Environmental Protection Agency. Accessed Oct 25, 2026
  4. 4.Technology Transitions GWP Reference Table. U.S. Environmental Protection Agency. Accessed Oct 25, 2026
  5. 5.Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps. U.S. Environmental Protection Agency (SNAP program). Accessed Oct 25, 2026
  6. 6.Deconstructing Flammable Refrigerants: The Who, What, Why, and How of Flammable Refrigerants (webinar, May 3, 2022). U.S. Environmental Protection Agency (GreenChill). Accessed Oct 25, 2026
  7. 7.40 CFR 84.7, Phasedown schedule. Electronic Code of Federal Regulations (U.S. EPA rule). Accessed Oct 25, 2026
  8. 8.Section 608 Technician Certification Requirements. U.S. Environmental Protection Agency. Accessed Oct 25, 2026
  • Ducted vs ductless heat pumpsDucted heat pumps deliver air through a duct system from one indoor coil, while ductless (mini-split) systems put one or more indoor units directly in the rooms they serve.
  • Heat pump ratings explained: SEER2, EER2, HSPF2 and AHRI certificatesSEER2, EER2 and HSPF2 are the federal efficiency ratings used since January 1, 2023, and an AHRI certificate shows them for one exact matched system.
  • Heat pumps in cold weatherAn air-source heat pump's capacity and efficiency both fall as the outdoor temperature drops; cold-climate models are tested at 5°F and must keep a COP of at least 1.75 there.
  • How heat pumps workA heat pump uses electricity to move heat between indoors and outdoors with a refrigerant loop, and a reversing valve lets the same equipment heat in winter and cool in summer.